Power Module with EcoSystem

The Power Module with EcoSystemR unit is a DIN-rail mounted EcoSystem Loop controller for EcoSystem ballasts, drivers and devices. It provides EcoSystemR Loop power and control for two independent EcoSystem Loops with up to 64 ballasts or drivers each.

Features

• Provides EcoSystemR Loop power for two loops of EcoSystemR ballasts or drivers (up to 250 mA per loop).

• Power failure memory retains control unit programming in the event of a power loss.

• Includes QS Link for connection to a HomeWorksR QS system.

• Power Module with EcoSystemR unit can be used in a HomeWorksR QS system to control and manage light in an entire home or building.

Power

• 120 V~ 50/60 Hz 120 mA

• 230 V~ 50/60 Hz 80 mA

• Lightning strike protection meets ANSI/IEEE standard 62.31-1980. Can withstand voltage surges of up to 6000 V~ and current surges of up to 3000 A.

• Stand by power: 7 W

• BTUs/hour when fully loaded: 24

• EcoSystemR Loop Output: 16 V- 250 mA maximum per loop.

Standards

• UL

• CE

• Lutron Quality Systems registered to ISO 9001.2008.

• C-Tick S

• cUL

• NOM

Environment

• Surrounding Air Temperature Range: 0 ?C to 65 ?C (32 ?F to 149 ?F).

• Relative humidity: less than 90% non-condensing.

• Calibration point maximum: 75 ?C (167 ?F)

• For indoor use only.

Terminals

• Mains wiring: 1.0 mm2 to 4.0 mm2 (18 AWG to 12 AWG)

• EcoSystemR Loop Wiring: 1,0 mm2 to 4,0 mm2 (18 AWG to 12 AWG)

• QS Wiring: 1,0 mm2 (18 AWG)

• Minimum wire temperature rating = 65 °C (149 ?F), Cu only

Mounting

• Intended to mount within an IP20 (minimum) rated consumer panel or breaker panel with integrated DIN rail and dead cover

• Width = 9 DIN modules (161.7 mm or 6 3 ?8 in).

Programming and Compatibility Requirements

• The LQSE-2ECO-D can only be used with the HomeWorksR QS system.

• Setup and programming of the Power Module with EcoSystemR is done through the HomeWorksR QS programming software

EcoSystemR

• Control up to 64 EcoSystemR-compatible devices (ballast or LED drivers) per EcoSystemR Digital Loop (up to 128 devices per Power Module with EcoSystemR unit).

• Digitally define areas and zones.

• Automatic replacement of a single failed ballast or driver.

• Simple method of replacing multiple failed ballasts or drivers.

• EcoSystemR Digital Loop can be wired as Mains voltage or IEC PELV/NECR Class 2 for maximum wiring flexibility.

• EcoSystem® Loop wires are polarity insensitive and topology-free.

EcoSystemR Digital Loop Limits

• Up to 64 EcoSystemR-compatible fluorescent ballasts and/or LED drivers per EcoSystemR digital loop.

• EcoSystemR-compatible fluorescent ballasts and LED drivers on the EcoSystemR digital loop do not count as QS devices.

QS Link Limits

• A QS link in a HomeWorks® QS system can have up to 512 zones (outputs) and 100 devices. A ballast or driver counts as 1 zone unless specifically grouped into zones from the HomeWorks® QS software.

• Each Power Module with EcoSystemR unit counts as one device toward the 100 device limit.

• A maximum of 8 fully loaded EcoSystemR digital loops may be connected to a single QS link.

HomeWorksR QS Wallstations

• HomeWorksR QS wallstations can be configured to control Power Module with EcoSystemR units with the HomeWorksR QS programming utility.

• LED indicator displays the status of programmed lights.

IEC PELV/NECR Class 2 QS Link Wiring

• Link communicates using IEC PELV/NECR Class 2 wiring.

• Follow all applicable national and local codes for proper circuit separation and protection.

• Wiring may be daisy chained or t-tapped.

• Total length of QS link must not exceed 610 m (2000 ft).

• Do NOT connect terminal 2.

• Wire Gauge - Power (terminals 1 and 2): 1 pair 1.0 mm( (18 AWG) - Data (terminals 3 and 4): 1 pair 0.5 mm( to 1.0 mm( (22 AWG to 18 AWG) twisted and shielded - Can use LutronR cable GRX-CBL-346S-500

 

Общие
Производитель
Lutron
Тип шлюза
QS link<> Eco Link
Подключение по шине
QS link
Выходы
Количество линий DALI
2
Напряжение питания линий DALI
18V
Ток линий DALI (максимальный пиковый)
250mA
Ток линий DALI (максимальный в рабочем режиме)
128mA
Электропитание
Напряжение питания
220V
Потребляемая мощность
-
Потребляемая мощность в режиме ожидания
7Вт
Потребляемый ток по шине
-
Цвет и габариты
Габаритные размеры
162 х 90 х 61 мм